Use and Operation
This valve is used to divert the flow from 2 ways in towards 4 ports (two at time alternatively). It’s ideal to control 2 actuators.
Materials and Features
- Body: zinc-plated steel
- Internal Parts: hardened and ground steel
- Seals: BUNA N standard
- Poppet Type: minor leakage
Applications
Connect P and P’ to the 2 pressure flows, ports A and B to the first actuator and ports A’ and B’ to the second actuator. With lever in position 1, P is connected to A and P’ to A’; with lever in position 2, P is connected to B and P’ to B’. Use with lever in central position is not recommended.