VEP - Two Pump "Hi-Low" Unloading Valves Flangeable On Low-Pressure Pump

Oleodinamica Marchesini In Stock
Code V0517 Type VEP FLP 1/2” Price €61.49 Quantity
Code V0521 Type VEP FLP 1/2” IFF 40 Price €92.95 Quantity

Use and Operation
This valve is used in a 2 parallel-working pumps circuit in order to release the excess of the higher flow pump to the tank when this gets the required pressure setting. Since this moment and on the actuator works with the lower flow pumps at higher pressure, consuming less energy. This valve is designed for direct flanging on lower flow pump. To adjust the high pressure, you have to mount a in line relief valve.

Materials and Features

  • Body: zinc-plated steel
  • Internal Parts: hardened and ground steel
  • Seals: BUNA N standard
  • Poppet Type: minor leakage

Applications
Connect BP to the higher flow pump, AP to the lower flow pump, T to the tank, M to the eventual manometer and U as for necessity.