Use and Operation
This valve is used to block pressure to a certain setting in the 2 ports of an hydraulic motor: when it reaches pressure setting, the valve opens allowing pressure relief in T. The relief valve provides overload protection in a fast and accurate way and cavitation is avoid tanks to the check valve. It’s suggested to mount set check valves to the tank way out.
Materials and Features
- Body: zinc-plated steel
- Internal Parts: hardened and ground steel
- Seals: BUNA N standard
- Poppet Type: minor leakage
Applications
Connect M1and M2 to the motor and P1 and P2 to the pressure flow. Connect T to the tank. Mounting by the actuator is highly recommended in order to avoid pressure drops and get a prompt duty.
On Request
- different setting range
- other setting available (CODE/T: please specify the desired setting)